Lab Models

 
   
ORBITEK L LX LD LR
Shaking Motion

ORBITAL

RECIPROCAL
Shaking Frequency 30-350 rpm

50-175 rpm

30-200 spm
Shaking Deviation +/- 2% of the set value
Shaking Amplitude

25 mm

Tray Dimension 420 X 420 mm 510 X 510 mm 420 X 420 mm 600 X 420 mm
RPM Indication Digital
Drive Permanent magnet DC Drive
Electrical Requirement 230 V, 5 Amps, 50 Hz.

LR

 

LT

 

 

Options

  • Illumination for photosynthetic application

  • Light bank consists of fluorescent lamps with individual lamp control

  • Programmable 24hrs timer with clock & UV lamps

  • Variety of throw

  • Lower and higher RPM

  • 0 - 5V out put for external Recording

  • Additional Tray for Petri Dishes

Top

 
ORBITEK LT LTH LTX
Shaking Motion

ORBITAL

 
Shaking Frequency

30-350 rpm

 
Shaking Deviation +/-2% of the set value  
Shaking Amplitude

25 mm

 
Tray Dimension

420 X 420 mm  

420 X 420 mm   510 X 510 mm
RPM Indication Digital
Drive Permanent magnet DC Drive
Temperature Range Ambient + 5oC - 60o C Ambient + 5oC - 80oC Ambient + 5oC - 60oC
Temperature Accuracy

+/- 0.1oC in 30~50oC range
+/- 0.4oC in the remaining region

Temperature Sensor

PT 100

Temperature Control PID control with pulse width modulation of heater
Heater Capacity 750 W
Electrical Requirement 230V,15 Amps, 50 Hz.

LT

LTIL

 

 

Options

  • Illumination for photosynthetic application
  • Light bank consists of fluorescent lamps with individual lamp control
  • Programmable 24hrs timer with clock & UV lamps
  • Humidity Measurement
  • Variable throw
  • Lower and higher RPM
  • 0 - 5V out put for external Recording
  • SS interior with drain for convenient clean in place
  • Additional Tray for Petri Dishes

Top

 
ORBITEK LE LEH LELH LEX
Shaking Motion ORBITAL
Shaking Frequency   30 - 350 rpm
Shaking Deviation +/- 2% of the set value
Shaking Amplitude

25 mm

Tray Dimension

420 X 420 mm

510 X 510 mm
RPM Indication Digital  
Drive Permanent magnet DC Drive
Temperature Range 15oC  - 60oC 15oC  - 80oC 7oC  - 80oC 15oC  - 60oC
Temperature Accuracy

+/- 0.1oC in 25~50oC range
+/- 0.4oC in the remaining region

Temperature Sensor

PT 100

Temperature Control PID control with pulse width modulation of heater
Heater Capacity 750 W
Electrical Requirement 230 V, 15 Amps, 50 Hz.
* Minimum temperature attainable at a maximum ambient of 45oC

Options

  • Illumination for photosynthetic application
  • Light bank consists of fluorescent lamps with individual lamp control
  • Programmable 24hrs timer with clock & UV lamps
  • Humidity Measurement
  • Variable throw
  • Lower and higher RPM
  • 0 - 5V out put for external Recording
  • SS interior with drain for convenient clean in place
  • Gas purging facility with HEPA filter for air
  • Additional Tray for Petri Dishes
  • Top open option available

LE

LEIL

LELH

       

CLAMPS

FLASKS L LX LR LT/LE LD WO WR
100 ml 36 49 35 36 36 16 08
250 ml 25 36 35 25 25 12 08
500 ml 16 25 20 16 16 6 4
1000 ml 9 16 12 9 - - -
2000 ml 4 09 - 4 - - -
     

Top